To read this content please select one of the options below:

Analysis of an n‐unit cold‐standby system with general failure and repair time distributions

M.N. Gopalan (Indian Institute of Technology, Bombay, India)
U. Dinesh Kumar (Indian Institute of Technology, Bombay, India)

International Journal of Quality & Reliability Management

ISSN: 0265-671X

Article publication date: 1 April 1995

326

Abstract

Analyses an n‐unit cold‐standby system with a single repair facility under the assumption that the failure and repair times are arbitrarily distributed. Develops a mathematical model using semi‐regenerative processes. Obtains a system of integral equations satisfied by various state probabilities corresponding to different initial conditions. Obtains explicit expressions for the expected number of failures and expected number of visits to down state in a specified interval of time. Discusses two special cases when either the failure or repair rate is constant. Analyses numerically and compares particular cases with one, two and three units by assuming Weibull distribution for failure time and normal distribution for repair time.

Keywords

Citation

Gopalan, M.N. and Dinesh Kumar, U. (1995), "Analysis of an n‐unit cold‐standby system with general failure and repair time distributions", International Journal of Quality & Reliability Management, Vol. 12 No. 3, pp. 77-85. https://doi.org/10.1108/02656719510084790

Publisher

:

MCB UP Ltd

Copyright © 1995, MCB UP Limited