Effects of alternating stray current on the corrosion behaviours of buried Q235 steel pipelines

Yanbao Guo (College of Mechanical and Transportation Engineering, China University of Petroleum, Beijing, China and Beijing Key Laboratory of Process Fluid Filtration and Separation, China University of Petroleum, Beijing, China)
Hai Tan (College of Mechanical and Transportation Engineering, China University of Petroleum, Beijing, China)
Deguo Wang (College of Mechanical and Transportation Engineering, China University of Petroleum, Beijing, China and Beijing Key Laboratory of Process Fluid Filtration and Separation, China University of Petroleum, Beijing, China)
Tao Meng (College of Mechanical and Transportation Engineering, China University of Petroleum, Beijing, China and Pressure Pipeline Division, China Special Equipment Inspection and Research Institute, Beijing, China)

Anti-Corrosion Methods and Materials

ISSN: 0003-5599

Article publication date: 6 November 2017

272

Abstract

Purpose

With the rapid development of rail transportation and energy-delivery systems, such as buried oil and gas pipelines and high-voltage transmission lines, the alternating current (AC) corrosion of buried steel pipelines is becoming more serious. This paper aims to study the corrosion behaviours of Q235 buried steel pipelines induced by the alternating stray current, with a set of indoor simulated experiment apparatuses.

Design/methodology/approach

The corrosion of the coating holidays of the buried steel pipelines at various AC current densities from 0 to 200 A/m2 in the soil-simulating environment was revealed by the electrochemical and weight-loss methods.

Findings

The results showed that the corrosion potential of the steel shifted negatively obviously and the corrosion rate of the steel increased with the increasing of AC current density. At a low AC current density, the negative deviation of the corrosion potential of the steel was small and the increase of corrosion rate was slight. However, the negative deviation of the corrosion potential was remarkable and the corrosion rate was greatly increased at a relative higher AC current density. The geometrical shape of the corrosion images indicated the corrosion forms changed from uniform corrosion to local corrosion due to the increase of AC interference.

Originality/value

Investigation results are of benefit to provide a new strategy to forecast and evaluate the AC-induced corrosion of the buried pipelines which could improve the safety of pipeline transportation.