The effects of using ceiling fans on human thermal comfort in a three-dimensional room with centralized heating including an occupant

Mahdi Ashoori (Department of Mechanical Engineering, University of Kashan, Kashan, Islamic Republic of Iran)
Ghanbarali Sheikhzadeh (Department of Mechanical Engineering, University of Kashan, Kashan, Islamic Republic of Iran)
Soroush Sadripour (Department of Mechanical Engineering, University of Kashan, Kashan, Islamic Republic of Iran and Department of Mechanical Engineering, University of Shahreza, Shahreza, Iran)

International Journal of Numerical Methods for Heat & Fluid Flow

ISSN: 0961-5539

Article publication date: 3 June 2019

Issue publication date: 17 October 2019

133

Abstract

Purpose

The purpose of this study is to analyze the effect of using a ceiling fan with central heating system in the winter on thermal comfort and heat transfer rate in a three-dimensional numerically.

Design/methodology/approach

The geometry had certain dimensions, and an occupant was modeled to be in the room. In models which were used, the flow was turbulent, and turbulence models were used for simulating turbulence. Between all the models, k-ε model had best matching.

Findings

Results show that using the ceiling fan during the winter had an efficient and considerable effect on improving the thermal comfort and energy saving inside buildings. By the use of ceiling fan, the effective room temperature has increased by 2.5°C. Furthermore, results show that by using ceiling fan in the winter, the predicted mean vote and the predicted percentage dissatisfied indexes improved. At the end, the case Room 11-0.05-15 with temperature of 87°C for radiator and normal fan velocity of o.25m/s were the optimal model that caused the complete thermal comfort and reduced energy consumption up to 28 per cent.

Originality/value

In the present study, the effects of using the ceiling fans on human comfort condition and heat transfer field during the winter (heating system) are studied. Following are the goals for all models: getting the appropriate temperature for radiator so that thermal comfort condition can be applied at the height of 75 cm of the room, velocity for fan so that air speed can be 0.25m/s at the height of 2 m or lower of the room and position to place the fan.

Keywords

Citation

Ashoori, M., Sheikhzadeh, G. and Sadripour, S. (2019), "The effects of using ceiling fans on human thermal comfort in a three-dimensional room with centralized heating including an occupant", International Journal of Numerical Methods for Heat & Fluid Flow, Vol. 29 No. 10, pp. 3976-3993. https://doi.org/10.1108/HFF-05-2018-0200