To read this content please select one of the options below:

Effect of flow rates on segmental baffle shell and tube heat exchanger using CuO-W nanofluids

Seralathan Sivamani (Department of Mechanical Engineering, Hindustan Institute of Technology and Science, Chennai, India)
Murugan M. (Department of Mechanical Engineering, Hindustan Institute of Technology and Science, Chennai, India)
Hariram Venkatesan (Department of Mechanical Engineering, Hindustan Institute of Technology and Science, Chennai, India)
Micha Premkumar T. (Department of Mechanical Engineering, Hindustan Institute of Technology and Science, Chennai, India)

World Journal of Engineering

ISSN: 1708-5284

Article publication date: 6 February 2020

Issue publication date: 19 February 2020

143

Abstract

Purpose

Nanofluid exhibits higher density, higher viscosity, higher thermal conductivity and reduced specific heat capacity along with improved heat transfer characteristics. It is comparatively better than conventional fluids in terms of thermo-physical properties. This paper aims to investigate experimentally the overall performance of the shell and tube heat exchanger operated under two different configurations – without baffles (STHX_1) and with baffles (STHX_2) using 0.01 Vol.% and 0.02 Vol.% of CuO-W nanofluid.

Design/methodology/approach

Two different configurations, one without baffles (STHX_1) and other with single segmental baffles (STHX_2), are chosen with all other dimensional details of shell and tube remaining same. Water is used as base fluid. CuO nanoparticle is chosen, as its thermal conductivity is higher compared to other metal oxides. A comparative study on the thermal performance of these shell and tube heat exchangers are performed by considering different Vol.% concentrations of CuO-W nanofluid and the outcome are compared with the base fluid (i.e., water). The influence of varying the mass flow rate of the tube side fluid by keeping shell side fluid mass flow rate as constant and vice versa on the thermal performance of shell and tube heat exchanger are studied.

Findings

The modified shell and tube heat exchanger with baffles (STHX_2) give an improved performance. The heat transfer coefficient improved by about 11.28 and 7.54 per cent for 0.02 and 0.01 Vol.% of CuO-W nanofluid compared to water. Overall heat transfer coefficient for STHX_2 enhanced between 118.26% to 123.06% in comparison with base fluid for 0.02 Vol.% of CuO-W nanofluid whereas, it improved between 79.20% to 87.51% for 0.01 Vol.% of CuO-W nanofluid. Similarly, the actual heat transfer enhanced between 71.79% to 77.77% and between 48.71% to 55.55% for 0.02 and 0.01 Vol.% of CuO-W nanofluid, respectively. Moreover, mass flow rates of the working fluids significantly influence the performance of the shell and tube heat exchanger.

Originality/value

Two cases are considered here. first, by varying the shell side fluid mass flow rate and keeping the tube side fluid mass flow rate as constant. Later, tube side fluid mass flow rates are varied and shell side fluid mass flow rate is kept constant. It is found that in Case 2, for both 0.01 and 0.02 Vol.% of CuO-W nanofluid, highest performance is obtained for 150 kg/h of shell side and tube side fluid flows involving STHX_2. Finally, the modified shell and tube heat exchanger with baffle arrangement gives the best performance by using 0.02 Vol.% of CuO-W nanofluid.

Keywords

Acknowledgements

The authors would like to acknowledge the anonymous reviewers for the peer review and giving suggestions to improve the quality of this paper.

Citation

Sivamani, S., M., M., Venkatesan, H. and T., M.P. (2020), "Effect of flow rates on segmental baffle shell and tube heat exchanger using CuO-W nanofluids", World Journal of Engineering, Vol. 17 No. 1, pp. 115-126. https://doi.org/10.1108/WJE-10-2019-0285

Publisher

:

Emerald Publishing Limited

Copyright © 2020, Emerald Publishing Limited