ISSN: 0332-1649
Online from: 1982
Subject Area: Electrical & Electronic Engineering
Content: Latest Issue |
Latest Issue RSS | Previous Issues
Options: To add Favourites and Table of Contents Alerts please take a Emerald profile
| Title: | A numerical evaluation of electromagnetic fields exposure on real human body models until 100?kHz |
|---|---|
| Author(s): | F. Dughiero, (Department of Electrical Engineering, University of Padova, Padova, Italy), M. Forzan, (Department of Electrical Engineering, University of Padova, Padova, Italy), E. Sieni, (INOVA LAB srl, Leinì, Italy) |
| Citation: | F. Dughiero, M. Forzan, E. Sieni, (2010) "A numerical evaluation of electromagnetic fields exposure on real human body models until 100?kHz", COMPEL: The International Journal for Computation and Mathematics in Electrical and Electronic Engineering, Vol. 29 Iss: 6, pp.1552 - 1561 |
| Keywords: | Electric current, Electromagnetism, Flux density, Magnetism |
| Article type: | Technical paper |
| DOI: | 10.1108/03321641011078625 (Permanent URL) |
| Publisher: | Emerald Group Publishing Limited |
| Acknowledgements: | This project has been developed in the frame of a research contract with Telwin SpA. |
| Abstract: | Purpose – The purpose of this paper is to describe how numerical models of human body have been applied for the evaluation of current density induced by strong magnetic field, to verify the respect of the basic restriction proposed by International Committee Non Ionizing Radiation Protection (ICNIRP) guidelines. Design/methodology/approach – Finite element method has been used in order to compute the induced current density in a suitable human body model and a simplified model – a homogeneous cylinder – due to a time-varying magnetic field. Findings – In the practical case of a resistance welding equipment, the implemented computational technique has been used in order to evaluate both the magnetic flux density and the induced current density in different tissues. Their values have been also compared with the ones obtained in a homogeneous cylinder. Practical implications – The proposed method can be used in order to evaluate the compliance of the magnetic field produced by resistance welding equipments with ICNIRP limits. Originality/value – A realistic model of human body has been used. In the paper, the difference on magnetic flux density and corresponding current density values is pointed out for various source positions using a heterogeneous tetrahedral human body model. |
Downloadable; Printable; Owned
HTML, PDF (224kb)
To purchase this item please login or register.
Complete and print this form to request this document from your librarian